Figure 48: Installing the cable clamp
▶ Only for AC PSU with cable clamp: Push the cable clamp into the
corresponding hole until it clicks in.
Once installed, the cable clamp cannot be removed and remains a part of
the PSU.
▶ Only for AC PSU with an hook-and-loop-tape: Before connecting the power
cord, attach the hook-and-loop tape to the handle.
Concluding steps
▶
"Connecting the power cord" on page
6.3.2
Removing a hot-plug PSU
Customer Replaceable
Unit (CRU)
Tools:
Phillips PH1 / (+) No. 1 screw driver (for DC PSU -48 V)
RX2540 M7
65.
Upgrade and Maintenance Manual
Power supply unit (PSU)
Hardware: 5 minutes
129