Electronic Thermal Warning - Omron MX2 Series User Manual

Multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

7 Other Functions
7-8-3

Electronic Thermal Warning

Use this function to output a warning signal before the motor electronic thermal function executes an
overload protection. In C061, set the warning level.
Set the Multi-function Output 11/12 Selection (C021/C022) or Multi-function Relay Output (AL1, AL2)
Function Selection (C026) to 13 (THM).
Parameter
No.
C061
C021, C022,
C026
*1. Set this in units of percentage as 100% of the overload trip level (E05).
7 - 78
Function name
Electronic Thermal Warning Level
Multi-function Output 11/12
Selection
Multi-function Relay Output (AL1,
AL2) Function Selection
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)
Data
0.
Electric thermal warning disabled
*1
1. to 100.
Set the output level of the thermal
warning signal.
13:
THM (Electronic thermal
warning)
Default
Unit
data
90.
%
7