3 Operation and Test Run
3-2-3

Precautions for Using CX-Drive

This section describes the precautions for using the "status function" and "test run function" of the
CX-Drive.
Status Function of CX-Drive
When the EDM function selector switch is ON, the input status of terminals GS1 and GS2 is displayed
for multi-function input terminals 3 and 4, respectively. Therefore, the "ON" or "OFF" state of 3 and 4 will
no longer be displayed.
Test Run Function of CX-Drive
By clicking the [Test Run] button in the toolbar, you can use the test run function.
Refer to the CX-Drive Operation Manual (Cat. No. W453) for details on the test run function.
• Before using the test run function, make sure that parameters are synchronized between the
CX-Drive and the Inverter. Parameters can be transferred with the [Transfer] button in the toolbar.
(Refer to Editing Parameter Data in CX-Drive on page 3-21.)
• In the test run function, following the setting of frequency, acceleration time, and deceleration time, all
parameters are transferred to the Inverter when the RUN command (forward/reverse) is executed.
Changing two or more settings simultaneously may result in a failure in parameter transfer.