2Nd Control Register Number List - Omron MX2 Series User Manual

Multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

8 Communications Functions
8-9-5

2nd Control Register Number List

Precautions for Correct Use
• The "Register No." in the table header shows the register number used inside the inverter.
Use this register number when setting EtherCAT communications.
• The "Modbus register spec. No." in the table header shows the register number used to actu-
ally specify the register in the Modbus communication process.
This register number is 1 less than the inverter "Register No." according to the Modbus com-
munication specifications.
⚫ Group F
Modbus
Register
register
No.
spec. No
2103 hex
2102 hex
2104 hex
2103 hex
2105 hex
2104 hex
2106 hex
2105 hex
2107 to
2200 hex
⚫ Group A/b/C/H/P
Modbus
Register
register
No.
spec. No
2201 hex
2200 hex
2202 hex
2201 hex
*1. If you change the 2nd RUN Command Selection setting, be sure to wait at least 40 ms before actually inputting
the RUN command.
8 - 96
Parameter
Function name
No.
F202
(HIGH)
2nd Acceleration
Time 1
F202
(LOW)
F203
(HIGH)
2nd Deceleration
Time 1
F203
(LOW)
Not used
Parameter
Function name
No.
2nd Frequency Ref-
A201
erence Selection
2nd RUN Command
A202
*1
Selection
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)
R/W
Monitor or setting data
R/W
0 to 360000
R/W
R/W
0 to 360000
R/W
Not accessible
R/W
Monitor or setting data
00:
Volume
01: Control circuit ter-
minal block (Ana-
log input)
02:
Digital Operator
03: Modbus communi-
cation
R/W
04:
Option
06:
Pulse train fre-
quency
07:
DriveProgramming
10:
Operation function
output
01:
Control circuit ter-
minal block (Drive-
Programming)
02:
Digital Operator
R/W
03:
Modbus communi-
cation
04:
Option
Data
Page
resolution
0.01 [s]
P. 5-32
0.01 [s]
Data
Page
resolution
P. 5-23
P. 5-21