Daily Inspection; Cleaning - Omron MX2 Series User Manual

Multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

11 Maintenance and Inspection

11-1-1 Daily Inspection

Check the following during operation.
• The motor operates according to the settings.
• There are no faults in the installation environment.
• There are no faults in the cooling system.
• There are no abnormal vibration and sound.
• There are no abnormal overheat and discoloration.
• There is no abnormal odor.
Check the input voltage of the inverter during operation by using a tester or other measuring equip-
ment.
• There is no frequent power supply voltage fluctuation.
• The line voltage is balanced.

11-1-2 Cleaning

Always keep the inverter clean.
Lightly wipe the exterior surfaces of the inverter with a soft cloth moistened with a neutral detergent to
remove dirt.
Do not use solutions such as acetone, benzene, toluene, or alcohol for cleaning. Doing so may cause
the inverter surfaces to dissolve or its coating to come off.
In particular, do not use any detergent or alcohol to clean the Digital Operator display.
11-1-3 Periodic Inspection
Check the parts that must be checked with the operation stopped, as well as those that require periodic
inspection:
• There are no faults in the cooling system.
→ Clean the air filter etc.
• Check for loose screws and retightening.
→ The screws, bolts, and other tightened parts may become loose due to vibration, temperature
change, or other influences. Check these parts carefully and retighten them if necessary.
• Check for corrosion or damage to conductors and insulators.
• Measure the insulation resistance.
• Check the cooling fan, smoothing capacitor, and relay.
• Refer to 7-10-4 Periodic Inspection on page 7-104 for periodic inspections for the safety function.
11 - 6
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)

Advertisement

Table of Contents
loading

Table of Contents