6 Vector Control and Applied Functions
Parameter
No.
H103
H104
A003
A004
A082
H105
b012
H109
H110
A051
b033
*1. The digit shift display mode can be used.
2
Auto-tuning
(1) Set the Auto-tuning Selection (H001) to 01 (Enabled: No motor rotation).
The available setting for PM motor auto-tuning is 01 (Enabled: No motor rotation) only. The
setting "02 (Enabled: Motor rotation)" is not displayed.
Parameter
No.
H001
(2) Turn ON the RUN command based on the setting in the 1st RUN Command Selection
(A002).
Turing ON the RUN command causes the inverter to start automatic operation, during
which auto-tuning is executed in the following sequence.
If auto-tuning is completed successfully, the auto-tuning result will be set to the parameters
H111 to H113.
1)
2)
3)
4)
6 - 60
Function name
0.1/0.2/0.4/0.55/0.75/1.1/1.5/2.2/3.0/3.7/4.0/
PM Motor Capacity
5.5/7.5/11.0/15.0/18.5
PM Motor Pole
2/4/6/8
Number
10 to 48: Do not set.
1st Base Frequency
30.0 to 1st Maximum Frequency (A004)
1st Maximum Fre-
1st Base Frequency (A003) to 400.0
quency
200-V class: 200/215/220/230/240
1st Motor Rated
Voltage Selection
400-V class: 380/400/415/440/460/480
PM Motor Rated
0.20  Rated current to 1.00  Rated current
Current
1st Electronic Ther-
0.20  Rated current to 1.00  Rated current
mal Level
PM motor Parame-
0.0001 to 6.5535
ter Ke
PM motor Parame-
0.001 to 9999.000
ter J
00:
DC Injection Brak-
01:
ing Selection
02:
Motor Cable Length
5. to 20.
Function name
00:
Auto-tuning Selec-
tion
01:
Initial pole position estimation (Motor does not rotate.)
1st DC excitation (Motor does not rotate.)
1st AC excitation (Motor does not rotate.)
2nd AC excitation (Motor does not rotate.)
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)
Data
*1
Disabled
Enabled
Enabled (Operates only at set frequency)
Data
Disabled
Enabled (No motor rotation)
Default data
Unit
Maximum
applicable
kW
motor
capacity
Dependent
pole
on capacity
60.0
Hz
60.0
Hz
200 or 400
V
Rated
A
current
Rated
A
current
Dependent
Vp/
on capacity
(rad/s)
Dependent
2
kgm
on capacity
00
10.
m
Default data
Unit
00

Advertisement

Table of Contents
loading

Table of Contents