Change of Maximum Frequency
The maximum frequency is changed from 400 Hz (580 Hz in high-frequency mode) to 590 Hz. For the
maximum frequency, refer to 5-3-3 Base Frequency and Maximum Frequency of Motor on page 5-20.
Precautions for Correct Use
If you must use the motor at higher than 400 Hz, use the high-frequency mode.
Changes in Reset Specifications
A trip caused by emergency shutoff (E37) can now be reset by the STOP/RESET key.
When STOP Key Selection (b087) is set to 00 (Enabled) or 02 (Only RESET enabled), reset can be
done according to Reset Selection (C102). After the reset, it operates according to the C103 setting.
The specifications of trip reset with RS (Reset) terminal remain unchanged from the 3G3MX2-E Series
Inverter.
Refer to 5-8-1 Reset on page 5-42 for information on the reset function.
Operation When Switching from Normal Operation to Jogging
Operation
When Jogging Stop Selection (A039) is set to 03 (Free-running on jogging stop/Enabled during
operation), 04 (Deceleration stop on jogging stop/Enabled during operation), or 05 (DC injection
braking on jogging stop/Enabled during operation), turning ON the jogging (JG) input during operation
will start jogging operation. The output frequency in switching to jogging operation is changed.
As for the details, refer to 5-9-6 Jogging (JG) on page 5-51 in Enabled during operation on page 5-52.
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)
1 Overview
1
1 - 37