Omron MX2 Series User Manual page 74

Multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

1 Overview
OFF/ON Operation of Cooling Fan
The operation when the Cooling Fan Operation (b092) is set to 01 (Enabled only during operation) or
02 (Dependent on cooling fin temperature) is changed as follows.
Refer to 7-8-13 Cooling Fan Operation on page 7-86 for cooling fan operation.
b092
00: Disabled
01: Enabled only during
operation
02: Dependent on
cooling fin temperature
Changes in Output Targets for Fatal Fault Signal (MJA) of
Multi-function Output
Regarding the fatal fault signal (MJA) of multi-function output, the errors that can be output are changed
as follows. The fatal fault signal (MJA) turns ON when an alarm indicated with "Yes" in the table below
occurs.
The 3G3MX2-EV2 Series Inverter does not output the MJA when a Current detector error (E10), CPU
communications error (E22), or Main circuit error (E25) occurs. Refer to 7-8-19 Fatal Fault Signal (MJA)
on page 7-89 for information on the fatal fault signal (MJA) of multi-function output.
Alarm
code
E08.
EEPROM error
E10.
Current detector error
E11.
CPU error
E14.
Ground protection
E22.
CPU communications error
E25.
Main circuit error
E30.
Driver error
1 - 42
3G3MX2-E
Constant operation
It operates under the following conditions.
• During operation (Stops 5 minutes after
operation stop)
• For 5 minutes after power-on
It operates under the following conditions.
• Cooling fin temperature of approxi-
mately 45°C or higher (Stops when it
falls below 45°C)
Description
3G3MX2-E
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)
Constant operation
It operates under the following conditions.
• During operation (Stops if fin tempera-
ture falls below 50°C for 3 minutes after
operation stop)
• Even while stopped, if fin temperature
exceeds 60°C (Stops if fin temperature
falls below 50°C for 3 minutes)
It operates under the following conditions.
Cooling fin temperature of approximately
40°C or higher (Stops if fin temperature
falls below 40°C for 3 minutes)
3G3MX2-EV2
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
3G3MX2-EV2
1