7-5-15 Stabilization Parameter

Use this function to stabilize the motor in hunting.
If the motor is hunting, check first whether the 1st/2nd Motor Capacity (H003/H203) and 1st/2nd Motor
Pole Number (H004/H204) settings match your motor and, if they do not, match them. If the motor's pri-
mary resistance is smaller than that of the standard motor, increase the value set in H006/H206 gradu-
ally. Or, to drive a motor with a capacity larger than the rated capacity of the inverter, reduce the set
value.
To suppress hunting, you can try the following methods as alternatives to this function.
• To decrease the Carrier Frequency (b083), refer to 7-4-1 Carrier Frequency on page 7-31.
• To decrease the 1st/2nd Output Voltage Gain (A045/A245), refer to 7-5-10 Output Voltage Gain on
page 7-41.
Parameter
No.
1st/2nd Stabilization
H006/H206
Parameter
1st/2nd Output Voltage
A045/A245
Gain
b083
Carrier Frequency

7-5-16 Pulse Train Frequency Input

Use this function to use the pulse train input (single-phase) to the terminal EA as a frequency reference
or PID feedback value in each control mode.
In the Pulse Train Frequency Scale (P055), set the input pulse train frequency at the maximum frequency.
This function cannot be used in conjunction with the analog input start/end function. To apply limits to
the pulse train frequency, set the Pulse Train Frequency Bias Amount (P057) and Pulse Train Fre-
quency Upper/Lower Limit (P058/P059). Set these values in units of percentage as 100% of the maxi-
mum frequency.
In addition, be sure to set the Pulse Train Frequency Upper Limit (P058) to a value larger than the
Pulse Train Frequency Lower Limit (P059). If the P058 value is lower than the P059 value, the inverter
will output only the upper limit frequency.
Parameter
No.
Pulse Train Input EA
P003
Selection
Pulse Train Frequency
P055
Scale
Pulse Train Frequency
P056
Filter Time Parameter
Pulse Train Frequency Bias
P057
Amount
Pulse Train Frequency
P058
Upper Limit
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)
Function name
0. to 255.
Increase or decrease the value if the motor
is hunting.
20. to 100.
Decrease the value if the motor is hunting.
2.0 to 15.0 or 2.0 to 10.0 (Heavy
load/Light load)
Decrease the value if the motor is hunting.
Function name
00:
1.0 to 32.0
Set the input pulse frequency to attain the
1st Maximum Frequency (A004).
0.01 to 2.00
Set the filter time constant for pulse train
input.
−100. to 100.
0. to 100.
Data
Data
Frequency setting or PID feedback
value
7 Other Functions
Default
Unit
data
100.
100.
%
10.0/2.0
kHz
Default
Unit
data
00
25.0
kHz
0.10
s
0.
%
100.
%