7 Other Functions
The main parameters related to frequency pull-in restart are as follows.
For details on free-run stop, refer to 5-7-2 Free-run Stop Selection on page 5-38.
Parameter
No.
b003
Restart Standby Time
Frequency Pull-in Lower
b007
Limit Frequency
Frequency Pull-in Restart
b028
Level
Frequency Pull-in Restart
b029
Parameter
Starting Frequency Selec-
b030
tion at Frequency Pull-in
Restart
7 - 64
Function name
0.3 to 100.0
Set the wait time until the inverter restarts.
0.00 to 590.00
Executing the function causes the Inverter to
restart from 0 Hz if the frequency at shutoff is
the set value of b007 or less.
0.20  Rated current to 2.00  Rated current
0.1 to 3000.0
Set the deceleration rate for the output fre-
quency during frequency pull-in restart.
Set the deceleration time from the maximum
frequency to 0 Hz.
00:
01:
02:
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)
Data
Frequency at shutoff
Maximum frequency
Set frequency (Frequency reference)
Default
Unit
data
1.0
s
0.00
Hz
7
Rated
current of
A
inverter
0.5
s
00