10 Troubleshooting

10-1-5 Other Indications on Digital Operator

Name
During reset
Undervoltage standby
Restart during
momentary power
interruption/Restart on
trip
Limited RUN command
Setting initialization
Trip monitor initialization
No data
Communications error
Auto-tuning OK
Auto-tuning NG
10 -
12
Description
This indication appears when the input terminal allo-
cated to the reset (RS) is ON, or when a trip state is
reset via the STOP/RESET key.
This indication appears when the inverter is in an
undervoltage standby state, or when the power sup-
ply is shut off.
This indication appears while restart operation is in
progress.
This indication appears when the RUN command is
input from the control terminal, with the RUN direc-
tion limited by the RUN Direction Limit Selection
(b035) setting.
This indication appears while the parameter settings
are initialized.
[ JP]: Pattern 0 setting
[ EU]: Pattern 1 setting
This indication appears while the trip monitor data is
initialized.
This indication appears when there is no applicable
data. (This indicates that the fault monitor has no trip
data.)
This indication appears on the remote Digital Opera-
tor if an error occurs between a remote Digital Oper-
ator and the Inverter. The indication on the Inverter
does not change.
This indication appears when auto-tuning is com-
pleted normally.
This indication appears when auto-tuning fails.
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)
Alarm code on
Digital Operator
Rotating
Only left most digit rotating
Only left most digit rotating
Only left most digit rotating
Blinking