Rs485 Terminal Arrangement And Connection - Omron MX2 Series User Manual

Multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

8 Communications Functions
8-2
RS485 Terminal Arrangement and
Connection
The communications terminals are arranged as follows.
EA
7
6
5
4
SP
SN
H
O
OI
RS485 terminal
3G3MX2 (No.1)
*1. If the communications are unstable, install a terminating resistor appropriate to the impedance of the cable to
each cable end. The resistance of the terminating resistor built into this inverter is 120 .
8 - 4
3
2
1
L
PLC P24 P24S
L
EO AM CM2 12
11
SP
SN
SP
SN
(No.2)
120 
SN
SP
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)
USB port is for computer
use only. RS422 (RJ45
modular connector) port
is for Digital Operator
use only.
Terminating resistor
selector switch
ON
OFF
(Factory default)
*1
SP
SN
120 
3G3MX2 (No.n)

Advertisement

Table of Contents
loading

Table of Contents