Simple Instruction Set Control; Host-To-Unit Instructions; Device-Initiated Power-Up Message; Password Prompt - Extron electronics DMP 128 Plus User Manual

12x8 prodsp digital matrix processor
Hide thumbs Also See for DMP 128 Plus:
Table of Contents

Advertisement

Tagged and Untagged Responses
When a query command is sent in verbose mode 0 or 1, only the "untagged" value is returned. When a query
command is sent in other verbose modes, the response is "tagged" and resembles the response to a set
command.
Examle: The gain query command
verbose mode:
Untagged (verbose 0 or 1): 626
Tagged (verbose 2 or 3): DsG40000*626
NOTE: All query responses listed in this guide are shown untagged.

Simple Instruction Set Control

Host-to-Unit Instructions

SIS commands consist of one or more characters per field. No special characters are required to begin or end a
command character sequence. When a command is valid, the transmitter executes the command and sends a
response to the host device. All responses from the transmitter to the host end with a carriage return and a line
]
feed (CR/LF =

Device-Initiated Power-Up Message

When the device completes its start-up, it issues the following message to the host:
© Copyright 2016-2022, Extron Electronics DMP 128 Plus {model}
Day, DD MMM YYYY HH:MM:SS
{model} is the full model name (for example, DMP 128 Plus C).
Vx.xx is the firmware version number
60-nnnn-nn is the part number of the unit
The DMP 128 Plus sends the boot and copyright messages under the following circumstances:
If the DMP 128 Plus is off and RS-232 connection is already set up (the PC is cabled to the DMP 128 Plus
and a serial communication program such as DataViewer is open), the connected unit sends these messages
via RS-232 when first powered on.
The DMP 128 Plus sends the boot and copyright messages when a Telnet connection to the DMP 128 Plus is
opened via Telnet, but not via RS-232. If using a Telnet connection, the copyright message, date, and time
may be followed by a password prompt.

Password Prompt

]
The
Password prompt requires an administrator or user password followed by a carriage return. The prompt is
repeated if the incorrect password is entered.
If the correct password is entered, the unit responds with
depending on the password entered. If passwords are the same for both administrator and user, the unit will
default to administrator privileges.
NOTES:
The factory configured password for this device is set to the device serial number. When performing a
factory reset, the password is set to the default password, which is no password.
Passwords are case sensitive. Passwords only apply to IP connections and can be up to 128
characters in length.
E
G40000AU
]
, just the gain value with no other information.
), which signals the end of the response character string. A string is one or more characters.
]
}
is sent. The following responses appear depending on the
]
, the type of query sent, the OID queried, and the gain value.
]
Login Administrator
DMP 128 Plus • SIS Configuration and Control
]
Vx.xx
60-nnnn-nn
,
,
]
]
or
Login User
]
33