Command
Reset to Factory Default (continued)
Full factory reset
Reset all device settings
and delete files
Player File Management
Set file to slot
association
Clear file to slot
association
View file to slot
association
X4&
KEY:
= Audio file name:
X4*
= Player ID:
Player Commands
Start playback on a
specific player
Stop playback on a
specific player
Player status
Set player repeat
Get player repeat status
Playback finished
X4*
KEY:
= Player ID:
X4(
= Repeat status:
X5)
= Play state:
Macro Commands
Run macro
Kill macro
Get macro status
Set macro name
Get macro name
Set power-on macro
Get power-on macro
X5!
KEY:
= Macro number:
X5@
= Macro status:
X5#
= Macro name:
ASCII command
(host to device)
E
}
ZQQQ
E
}
ZY
E
X4*
X4&
}
A
*
CPLY
E
X4*
}
A
*•CPLY
E
X4*
}
A
CPLY
A-Z
Valid characters are
1
8
through
EX4*
}
*1PLAY
EX4*
}
*0PLAY
EX4*
}
PLAY
E
X4*
X4(
}
M
*
CPLY
E
X4*
}
M
CPLY
Unsolicited
1
8
through
0
1
= Play once
= Repeat
0
1
= Stopped
= Playing
E
X5!
}
R
MCRO
E
X5!
}
K
MCRO
E
X5!
}
S
MCRO
E
X5!
X5#
}
A
*
MCRO
E
X5!
}
A
MCRO
E
X5!
}
P
MCRO
E
}
PMCRO
1
64
through
. Response will be padded with a leading
0
1-32
= Macro idle
24 characters maximum (
Response
(device to host)
]
Zpq
]
Zpy
X4*
X4&]
CplyA
*
X4*
]
CplyA
*•
X4&]
a-z
0-9
_
,
,
,
X4*
]
Play
*1
X4*
]
Play
*0
X5)]
X4*
X4(]
CplyM
*
X4(]
X4*
]
Play
*0
X5!]
McroR
X5!]
McroK
X5@]
X5!
X5#]
McroA
*
X5#]
X5!]
McroP
X5!]
= Macro step
A-Z
a-z
0-9
-
,
,
, and "
")
DMP 128 Plus • SIS Configuration and Control
Additional description
Reset excludes IP address,
subnet mask, gateway IP
address, unit name, DHCP,
and port mapping in order
to preserve communication
with the device.
Turning off repeat during
playback will stop playback
after current iteration.
0
Using
for
power-on macro
assignment.
0
.
X5!
clears
49