Digital Input —
If the input voltage is lower than 0.8 V, it is considered logic "LOW."
If the input voltage is lower than 0.8 V, it is considered logic "LOW."
If the input voltage is greater than 3.0 V, it is logic "HIGH."
The maximum input voltage is 12.0 VDC.
Digital Output —
The output port has an internal pull up to 5 V.
The output "LOW" is less than 0.7 V.
The output "HIGH" is greater than 3.5 V.
The maximum output voltage is 5.0 VDC.
Mic/Line inputs (see
C
screw connectors to connect eight mono balanced or unbalanced microphone or line level sources (see
figure 4 for wiring details). For all models, Inputs 1 through 8 provide phantom power. For C models, Inputs 1
through 12 provide AEC.
On inputs 9 through 12, use 3-pole or 6-pole 3.5 mm captive screw connectors to connect up to four mono
balanced or unbalanced microphone or line level sources, or two stereo sources (see figure 4 and figure 5 for
wiring details).
Tip
Ring
Sleeve
Balanced Input
Figure 4.
Audio Input Wiring
Tip
Ring
Sleeve
Tip
Ring
Sleeve
Balanced Input
Figure 5.
Audio Output Wiring
ATTENTION:
Condenser microphones require phantom power.
Les microphones électrostatiques nécessitent une alimentation fantôme.
Dynamic microphones do not need power.
Les microphones dynamiques n'ont pas besoin d'alimentation.
When a line level source is connected, be certain the +48 V phantom power is off (cleared).
Lorsqu'une source de niveau ligne est connectée, soyez certain que l'alimentation fantôme +48 V
est débranchée (enlevée).
figure 2
on page 4) — On inputs 1 through 8, use the included 3-pole 3.5 mm captive
3
" (5 mm) MAX.
16
Sleeve
3-pole Audio INPUT Wiring
Tip
Sleeve
Jumper
Tip
Sleeve
Jumper
6-pole Audio INPUT Wiring
Tip
Jumper
Unbalanced Input
Unbalanced Input