Symbol Definitions

]
= CR/LF (carriage return with line feed)
|
}
or
= Soft carriage return (no line feed)
= Space
E
or W = Escape key
NOTES:
If unit does not support or recognize the entered commands, nothing happens and no response is
issued.
Only instances marked with a
command and response tables are only inserted for ease of reading.
KEY:
X!
Port Number — 01 (always 01 for DMP 128 Plus)
=
X@
GMT Offset Value — This represents hours and minutes (hh:mm) offset from Greenwich Mean Time.
=
X#
Unit Name — A text string up to 63 characters drawn from the alphabet (A-Z), digits (0-9), and minus sign/
=
hyphen (-).
X$
Local Date and Time Format — MM/DD/YY-HH:MM:SS
=
X%
IP address (xxx.xxx.xxx.xxx) — Leading zeros in each of the 4 fields are optional in setting values and
=
are suppressed in responses.
X^
Hardware MAC Address — 00-05-A6-xx-xx-xx
=
X&
Subnet Mask (xxx.xxx.xxx.xxx) — Leading zeros in each of the 4 fields are optional in setting values and
=
are suppressed in responses.
Dante Device Name — Device names are not case sensitive.
X*
=
X(
Verbose/Response mode —
=
X1)
Baud Rate — 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600, 14400, 19200, 28800, 38400 (default),
=
57600, or 115200
X1!
Parity (only the first letter is needed) —
=
X1@
Data Bits — 7, 8 (default = 8)
X1#
Port Type — 0 = RS-232 (default)
=
Flow Control (only the first letter is needed) —
X1$
=
X1%
Data Pacing — Specified in milliseconds between bytes. 0000-1000 ms (default is 0 ms). For host port or
=
ports, this value is ignored and always returns a 0.
X1^
Password — 0-128 characters. All human-readable characters are permitted except "|". Password cannot
=
be a single space. Passwords are case-sensitive.
X1&
Reading Password — Responds with 4 asterisks (****) if password exists and empty if not, instead of
=
actual password.
X1*
Default Name — A combination of the model name and the last 3 pairs of the MAC address of the unit.
=
Serial Port — 1-n = Redirect serial port data from the specified port to allow for a transparent pass through
X1(
=
mode.
X2)
Connection Security Level — 11 = User
=
character require a space. Any spaces between characters in the
0 = Clear/none (default for Telnet connections)
1 = Verbose mode (default for USB and RS-232 host control)
2 = Tagged responses for queries
3 = Verbose mode and tagged responses for queries
O = odd
S = space
12 = Administrator
DMP 128 Plus • SIS Configuration and Control
E = even
M = mark
H = hardware
S = software
N = none (default)
N = none (default)
35