X2@
Date and Time in Hex — Date and time returned in 7 hex bytes (month, day, year, hour, minutes, seconds,
=
and day of the week with Sunday = 1)
X2#
IP Timeout — The number of seconds before timeout on IP connections (min = 1, max = 65000 and default
=
= 30 [300 secs]). If no data is received during the timeout period, the Ethernet connection will be closed.
Each step = 10 seconds.
X2$
Extron Remote Connection Mode — 0 = Disabled
=
X2%
Stop Bits — 1, 2 (default = 1)
=
X2^
NTP Status — 0 = Disabled (default)
=
X2&
Configuration Type — 0 = IP configuration
=
X2*
Firmware Query —
=
X2(
NIC Number — Network Interface Card number 1 or 2 (only V-models have 2 NICs)
=
X3)
Prefix (subnet mask bits) — Subnet 255.255.0.0 is represented as a Prefix value of /16.
=
X3!
Text — Up to 64 characters.
=
Digital Input Status — 0 = Logic low
X3@
=
X3#
Digital I/O Channel — 1 through 8
=
X3$
DHCP Status —
=
X3%
Action Type — 0 = No action/off
=
0 = Detailed version information (includes all 2Q, 3Q, and 4Q)
1 = Firmware Version
2 = Final Stage bootloader
0 = Off (default)
Mutes
1 = Level trigger (low mutes)
2 = Level trigger (high mutes)
3 = Edge trigger (high to low mutes, low to high unmutes)
4 = Edge trigger (high to low unmutes, low to high mutes)
5 = Toggle trigger (high to low toggles mute)
6 = Toggle trigger (low to high toggles mute)
Group Mutes
7 = Level trigger (low mutes)
8 = Level trigger (high mutes)
9 = Edge trigger (high to low mutes, low to high unmutes)
10 = Edge trigger (high to low unmutes, low to high mutes)
11 = Toggle trigger (high to low toggles mute)
12 = Toggle trigger (low to high toggles mute)
Macros
13 = Edge trigger (high to low starts macro)
14 = Edge trigger (low to high starts macro
Presets
15 = Edge trigger (high to low recalls preset)
16 = Edge trigger (low to high recalls preset)
1 = Enabled
1 = Enable
2 = Device-specific parameters
3 = Factory base code version
4 = Updated firmware version
1 = Logic high
1 = On
DMP 128 Plus • SIS Configuration and Control