Extron electronics DMP 128 Plus User Manual page 46

12x8 prodsp digital matrix processor
Hide thumbs Also See for DMP 128 Plus:
Table of Contents

Advertisement

X6$
Group Fader Setting — dB, value in 0.1 dB increments using a 10x multiplier and negative numbers, but
=
not decimal places. The valid range depends on the type of gain block that is assigned to the group number
X6)
specified in the command:
-180 to 800 (-18 dB to +80 dB)
-1000 to 120 (-100.0 dB to +12.0 dB)
-120 to 120 (-12.0 dB to +12.0 dB)
-1000 to 0 (-100.o dB to +0.0 dB)
NOTE: Leading zeros are ignored.
X6%
Group Fader Increment —
=
10x multiplier (+10 dB = 100+). + or - goes after the number.
X6^
Group Fader Soft Limit —
=
X6&
Group Type — 6 = Gain
=
X6*
Unsolicited Meter Rate (responses per second) —
X6(
Unsolicited Meter Group Setting — 0 disables unsolicaited meter responses, 1-64 specifies/enables a
meter group for unsolicited meter value responses; 0 at power on.
Source Mode —
X7)
=
0 = Disabled
1 = File/Tone Playback: Player 1
2 = File/Tone Playback: Player 2
3 = File/Tone Playback: Player 3
4 = File/Tone Playback: Player 4
5 = File/Tone Playback: Player 5
6 = File/Tone Playback: Player 6
7 = File/Tone Playback: Player 7
8 = File/Tone Playback: Player 8
X7!
Update Status — 0 = Disabled
=
X7@
Meter Level — -150.0 dBFS to 0.0 dBFS (1500 to 0000)
=
X7#
Output Mode —
=
0 = Disabled
1 = USB 1 Tx: Left Channel
2 = USB 1 Tx: Right Channel
3 = USB 2 Tx: Left Channel
4 = USB 2 Tx: Right Channel
5 = USB 3 Tx: Left Channel
X7$
Gate Monitoring Status — 0 = Gate monitoring disabled
=
X7%
Meter Status — 0 = Meter off
=
X7^
Monitoring Threshold — 0 = Disabled
=
-100.0 dBFS)
X7&
Meter Value — 0000-2000 = 0.0 to -200.0 dBFS
=
X7*
Meter Relative to Threshold — 0 = Above threshold
=
X7(
Signal level when gate is opened or closed — 0000-1023 = gate closed, ≥1024 = gate opened (see
=
Automixer Gate Monitoring
Line Number — 1-8
X8)
=
X8!
Appearance Number — 1-8 (where 1 is originating two-party call)
=
X8@
Phone Number — No spaces allowed. Valid characters are 0-9, *, #.
=
dB value, in 0.1 dB increments, to raise or lower a group fader. Gain uses
dB value, in 0.1 dB increments. Gain uses 10x multiplier (+10 db = 100+).
12 = Mute
1-10; default is 1 (for firmware before v1.11.0000-b006)
1-25; default is 1 (for firmware v1.11.0000-b006 or higher)
on page 55 for more details).
21 = Meter
9 = USB 1 Rx: Left Channel
10 = USB 1 Rx: Right Channel
11 = USB 2 Rx: Left Channel
12 = USB 2 Rx: Right Channel
13 = USB 3 Rx: Left Channel
14 = USB 3 Rx: Right Channel
15 = USB 4 Rx: Left Channel
16 = USB 4 Rx: Right Channel
17 = VoIP Line 1 Rx
1 = Enabled
6 = USB 3 Tx: Right Channel
7 = USB 4 Tx: Left Channel
8 = USB 4 Tx: Right Channel
9 = VoIP Line 1 Tx
10 = VoIP Line 2 Tx
11 = VoIP Line 3 Tx
1 = Meter on
0001-2000 = Signal threshold to monitor (-0.1 to
1 = Equal to or below threshold
DMP 128 Plus • SIS Configuration and Control
18 = VoIP Line 2 Rx
19 = VoIP Line 3 Rx
= VoIP Line 4 Rx
20
21 = VoIP Line 5 Rx
22 = VoIP Line 6 Rx
23 = VoIP Line 7 Rx
24 = VoIP Line 8 Rx
12 = VoIP Line 4 Tx
13 = VoIP Line 5 Tx
14 = VoIP Line 6 Tx
15 = VoIP Line 7 Tx
16 = VoIP Line 8 Tx
1024 = Gate monitoring enabled