Command
Automixer Gate Monitoring
Get current automixer
gate status
Unsolicited automixer
gate status update
X7$
KEY:
= Gate monitoring status:
X7%
= Meter status:
X7*
= Meter relative to threshold:
X7(
= Signal level when gate is opened or closed.
X9(
= Target OID:
Signal Level Monitoring (SLM)
SLM tracks when the signal at a metered gain OID crosses a set threshold level. When SLM is enabled for an OID, an unsolicited message is sent
when the threshold level is crossed. The response includes the OID, meter on/ off status, level after the threshold was crossed, and if the level was
going up or down when the threshold was crossed.
Set SLM status
Get current threshold
status
Unsolicited meter value
X5%
KEY:
= Target OID:
X7%
= Meter status:
X7^
= Monitoring threshold:
X7&
= Meter value:
X7*
= Meter relative to threshold:
ASCII command
(host to device)
E
X9(
}
J
AU
This is enabled by selecting
the Automix dialog Monitor
Gate checkbox in DSP
Configurator (see the DSP
Configurator Help File for details).
0
= Gate monitoring disabled
1
= Meter off
0
= Above threshold
0000-1023
See
Automixer OIDs
E
X5%
X7^
}
J
*
AU
E
X5%
}
J
AU
Object ID (OID) Number Tables
See
1
= Meter off
0
= disabled
0000
2000
-
= 0.0 to -200.0 dBFS
0
= Above threshold
Response
(device to host)
X7$]
X5%
X7%
X7(
X7*]
DsV
*
*
*
1024
= Gate monitoring enabled
2
= Meter on
1
= Equal to or below threshold
1024
= gate closed, ≥
= gate opened.
on page 61.
X5%
X7^]
DsJ
*
X7^]
X5%
X7%
X7&
X7*]
DsV
*
*
*
on page 58.
2
= Meter on
0001
2000
-
= signal threshold to monitor (-0.1 to -200.0 dBFS).
1
= Equal to or below threshold
DMP 128 Plus • SIS Configuration and Control