Connection Details

TP Cable Termination for Ethernet Communication

It is vital that your Ethernet cable be the correct cable type and that it be properly terminated with the correct
pinout. Ethernet links use Category (CAT) 3, 5e, or CAT 6, unshielded twisted pair (UTP) or shielded twisted pair
(STP) cables, terminated with RJ-45 connectors. Ethernet cables are limited to a length of 328 feet (100 meters).
The cable can be terminated as either a patch cable or a crossover cable (see figure 10) and must be properly
terminated for the application:
Patch (straight-through) cable — Connection of the device to an Ethernet hub, router, or switch that also
hosts a controlling computer.
Crossover cable — Direct connection between the processor and a controlling computer
Pins:
1 2 3 4 5 6 7 8
Insert Twisted
Pair Wires
RJ-45
Connector
Figure 10.
RJ-45 Pin Assignment for Ethernet Connection

Reset Modes

The rear panel Reset button initiates three levels of resets. Use a pointed stylus, ballpoint pen, or small
screwdriver to access the recessed button.
Reset Modes
See the
ATTENTION:
Review the reset modes carefully. Some reset modes delete all user loaded content and revert the
device to default configuration.
Analysez minutieusement les différents modes de réinitialisation. Certains modes de réinitialisation
suppriment l'intégralité du contenu chargé de l'utilisateur et remettent l'appareil au mode de
configuration par défaut.
NOTE: The reset modes listed in the
sockets.
Crossover Cable
(for direct connection to a PC)
End 1
Pin
Wire Color
Pin
1
white-orange
1
2
orange
2
3
white-green
3
4
blue
4
5
white-blue
5
6
green
6
7
white-brown
7
8
brown
8
T568B
A cable that is wired as TIA/EIA T568A at one
end and T568B at the other (Tx and Rx pairs
reversed) is a "crossover" cable.
on page 10 for a summary of the reset.
Reset Modes
Straight-through Cable
(for connection to a switch, hub, or router)
End 2
End 1
Wire Color
Pin
Wire Color
white-green
1
white-orange
green
2
orange
white-orange
3
white-green
blue
4
blue
white-blue
5
white-blue
orange
6
green
white-brown
7
white-brown
brown
8
brown
T568A
T568B
A cable wired the same at both ends is called
a "straight-through" cable because no pin/pair
assignments are swapped.
table close all IP connections, Telnet connections, and
End 2
Pin
Wire Color
1
white-orange
2
orange
3
white-green
4
blue
5
white-blue
6
green
7
white-brown
8
brown
T568B
DMP 128 Plus • Installation