Power cables
■
Typical power cables, IEC
The table below gives copper cable types with concentric copper shield for the
drives with nominal current. The value separated by the plus sign means the
diameter of the PE conductor.
See page
330
for the cable entry sizes allowed for the selected drive frame size.
ACS580-01-...
3-phase U n = 230 V
04A7-2
06A7-2
07A6-2
012A-2
018A-2
025A-2
032A-2
047A-2
060A-2
089A-2
091A-2
115A-2
144A-2
171A-2
213A-2
276A-2
3-phase U n = 400 V
02A7-4
03A4-4
04A1-4
05A7-4
07A3-4
09A5-4
Frame size
R1
R1
R1
R1
R1
R2
R2
R3
R3
R5
R4 v2
R5
R6
R7
R7
R8
R1
R1
R1
R1
R1
R1
1)
Cu cable type
mm 2
3×1.5 + 1.5
3×1.5 + 1.5
3×1.5 + 1.5
3×1.5 + 1.5
3×2.5 + 2.5
3×4.0 + 4.0
3×6.0 + 6.0
3×10 + 10
3×16 + 16
3×35 + 16
3×50 + 25
3×50 + 25
3×70 + 35
3×95 + 50
3×120 + 70
2×(3×70 + 35)
3×1.5 + 1.5
3×1.5 + 1.5
3×1.5 + 1.5
3×1.5 + 1.5
3×1.5 + 1.5
3×2.5 + 2.5
Technical data 337
1)
2)
AI cable type
,
mm 2
-
-
-
-
-
-
-
-
-
3×50 + 25
3×70 + 35
3×70 + 35
3×120 + 70
3×150 + 70
3×240 + 120
2×(3×95 + 50)
-
-
-
-
-
-