Disable. Ignores the SGEA command from the host. The printer does not stop when an error is
detected; instead, it substitutes the character selected in the Graphic Chek Code parameter.
Graphic Chek Cod
Specifies the replacement character to print in place of any unprintable character that is received from the
host. Choose a hex character from 40 through FE. The character becomes the printer default when:
The printer is powered off and then powered on.
An SGEA command specifies to use the operator panel default.
The Graphic Chek Err parameter is disabled.
The value can be the following:
60 (factory default)
40 – F4
Set Text Orientn
Specifies the direction in which characters are printed on the page. This allows the printer to print
languages which are printed right to left instead of left to right.
Left to Right (factory default)
Right to Left. When a right to left language is selected, the host will be notified of print direction
changes when the printer is put online.
Host Override
Determines whether the printer accepts certain commands sent by the host, or continues to use the
current operator panel settings.
Disable (factory default). Allows these host commands to override operator panel settings: line
length, forms length, lines per inch (LPI), characters per inch (CPI), print quality, and text orientation.
Note the information appearing on the message display may not match the data stream setting. No
values will change upon initial selection of the disable option.
Enable. The operator panel settings override the host commands.
Format Control
Enables the printer to reflect the same spacing as earlier generation line matrix printers after absolute and
relative move commands are executed.
Disable (factory default). Reflects distance, generated by the VGL feature, PGL feature, and Hex
Transparent control code sequence, in the new position (after horizontal and vertical tabs are
executed).
Enable.
Max. Print Width
Set the maximum print width the printer will print when using an IBM host interface. Set for 13.2 inches
when printing files larger than the width of the printer. All data exceeding the width of the maximum
Printer Width will be truncated.
13.2 Inches (factory default)
Printer Width (the maximum width of the printer)