120 V transformer (AO367335 or equivalent). The following minimum
specifications must be met by this transformer:
Input voltage: 120 V AC / 60 Hz
No load output voltage: 29 V AC maximum
Voltage at rated current: 26.7 V AC minimum
Rated load current: 700 mA
240 V transformer (AO367914 or equivalent). The following minimum
specifications have to be met by this transformer:
Input voltage: 240 V AC / 50 Hz
No load output voltage: 29 V AC maximum
Voltage at rated current: 26.7 V AC minimum
Rated load current: 700 mA
Note: You cannot wall mount the telephone over the wall jack when
using a transformer, due to the size of the RJ-11 adapter. Hang it above
or to the side of the jack and run the line and power cords to it.
Closet power supply
Closet power can be obtained from an AC transformer for loops of 100 ft.
(30 m) or less, or a DC transformer for loop lengths of 650 ft. (197 m) or less.