Page 118 of 532
553-3001-367
Standard 1.00
Procedure 17
Connecting the BLF/CGM to the M2250 attendant console
1
Disconnect the main power/system cable from the rear of the attendant
console, and remove the handset jack plug from the side.
2
Move the adjustable display to the down position to protect it from
damage while installing the Busy Lamp Field/Console Graphics Module
(BLF/CGM). Move the volume slider switch to the far left. See Figure 26.
Figure 26
Volume slider position
3
Place the attendant console facedown on a properly prepared work
surface, taking care to avoid scratching or damaging the top cover or
display. Remove the adjustable stand, if required.
The stand is secured with four screws. Remove the stand as a complete
assembly, and set aside.
4
Remove the 12 fastening screws in the base of the attendant console that
secure the top cover to the console base. See Figure 27 on
Holding the console base and cover firmly, turn it over so that the top
cover is on, facing up.
October 2003
Move Volume Slider
to left-most position
553-AAA0626
page