18 Slide the ribbon cable connector onto the connector pins (P2 on an NTZK
M2008, J3 on an NT2K M2008, and P4 on an M2616) on the mother
board.
CAUTION
This connection is polarity sensitive.
19 Ensure that the pins line up with the connector correctly and carefully
work the connector on until it is firmly seated.
Reattaching the Base
20 Make sure the ribbon cable is lying flat and not caught over or under any
alignment posts or studs on the telephone base. (For the M2616, allow it
to cover the screw post and do not replace the screw on re-assembly.)
21 Replace the base.
22 Insert all screws (except the center screw on the M2616) and tighten
them.
Reattaching the Footstand
23 If the telephone has a Meridian Programmable Data Adapter (MPDA) or
Meridian Communications Adapter (MCA), plug its cable into the jack on
the telephone base.
24 Replace the footstand, positioning it firmly on the base.
25 Insert and tighten all screws.
Note: Place the label supplied with the display on the outside of the
bottom cover of the telephone. This allows proper identification and
tracking of the option level of the set.
Reconnecting the Telephone
26 Reconnect all cords.