Page 230 of 532
Designating keys on the attendant console
553-3001-367
Standard 1.00
3
Press the F4 Function key to access the Diagnostics menu on the LCD
screen.
4
Plug the loopback connector into the Data Port RS-232 jack in the back
of the console.
5
Select the Data Port option from the Diagnostics menu by dialing "3". The
LCD screen displays OK when the test is successfully completed.
If there is a hardware fault on the M2250, A0H is displayed.
If the blank RS-232 connector is not plugged into the data port correctly
(as described in Step 4), the display reads 90H or A0H.
6
Press the asterisk (*) key to repeat the test.
7
To exit the test mode press the octothorpe (#). to return to the main
Diagnostics menu.
8
Press the octothorpe (#) to return to normal operating mode.
9
Remove the loopback connector from the Data Port RS-232 jack.
Refer to the work order to determine the features and key designations for
each attendant console. Designate each key on the attendant console by
placing its feature name (from the designation sheet) in the key cap that fits
on the key.
The Directory Number (DN) designation window on the M2250 attendant
console is located above the keypad.
Follow the steps in Procedure 43 to designate keys on an M2250 attendant
console.
Procedure 43
Designating keys on an M2250 attendant console
1
Remove the cap from each key requiring a designation by gently pulling
upward on the cap.
2
Remove the appropriate designation from the sheet of designations.
October 2003
End of Procedure