Nortel Meridian 1 Succession 1000 Description page 181

Telephones and consoles
Hide thumbs Also See for Meridian 1 Succession 1000:
Table of Contents

Advertisement

9
To signal the External Alerter when the telephone's handset or speaker is
active, place the jumpers (AO288529) connecting the two right-most pins
on the alerter board.
To signal the External Alerter when the telephone is ringing or buzzing,
place the jumpers connecting the two left-most pins on the External
Alerter Board.
10 If the telephone is not yet equipped with the power supply board, install it
(see Procedure 13 for M2006/M2008; see Procedure 28 on
M2616/M2016S/M2216ACD).
Note: Do not allow R5 on the power supply board to become bent during
this procedure.
11 Replace the base. If the telephone is equipped with an MPDA or MCA,
reconnect the data cable to the base telephone jack and replace the
footstand (ensuring that the MPDA or MCA cable does not get pinched
between the base and the footstand). Make sure the footstand is firmly
seated in the base.
12 Tighten all screws, reconnect the line cord, and place the telephone in the
normal operating position.
Note: Place the label supplied with the External Alerter on the outside of
the bottom cover of the telephone. This allows proper identification and
tracking of the option level of the set.
13 For the connecting block configuration, see Figure 51.
14 Perform the self-test (see Procedure 4 on
procedures. See LD 31 in the Software Input/Output: Administration
(553-3001-311).
M2000 add-on modules
page
End of Procedure
Telephones and Consoles
Page 181 of 532
page 157
57) and acceptance test