Table 18
Loop lengths for digital telephones
PVC insulated cable (polyvinyl chloride)
22 or 24 AWG
26 AWG
Note 1: No bridge taps or loading coils are allowed.
Note 2: Effect of line protector at MDF reduces loop length by 500 ft.
Power requirements
lengths are possible, depending on the wire's gauge and insulation.) Table 18
gives detailed information on loop lengths.
CAUTION
Damage to Equipment
Service Interruption
Use only the line cord provided with the M2000
Series Meridian Digital Telephone. Using a cord
designed for other digital telephones could result in
damage to the cord or a loss of set functionality.
The M2006, M2008, M2008HF, M2616 (basic configuration and with
Display module), and M2216ACD-1 are loop powered. Loop power,
originating in the ISDLC or the DLC, consists of a 30 V dc power source and
assumes a 3500 ft. (1219 m) maximum loop length of 24 AWG (0.5 mm)
wire and a minimum 15.5 V dc at the telephone terminals.
Note: The loop length limit is defined by a 15.5 dB loss at 256 KHz.
Longer lengths can be determined using the wire's gauge and insulation.
M2000 description
Telephones and Consoles
Page 103 of 532
NT8D02
0–3500 ft.
(0–1067 m)
0–2600 ft.
(0–793 m)