Chapter 10
Setting SNMP Traps
Annex Manager User Guide
10-2
Understanding the SNMP Settings Window
The
window displays information in the
SNMP Settings
SNMP Settings Box
The SNMP Settings box allows you to enter information in the
and
Traps For
Call History
•
The
Generate Traps For box
–
Check buttons to enable or disable SNMP traps. The default
value is disabled. When you click the check button of a trap
to enable it, the threshold value in the corresponding field is
set to the number 1. If you set the threshold value to 0, the
trap is automatically disabled. You can select:
•
Call Begin
detected or an outbound call is generated by the Annex.
•
Call End
•
Unexpected Call disconnect
disconnects unexpectedly.
•
Forced Call Disconnect
disconnected.
•
Modems Failed to Connect
modem failure is detected automatically and the
modem is busied out. The message specifies the
modem which is busied out.
•
Dial up Link up/down
traps for remote dial-in interfaces.
–
Text fields to set threshold values. You can select:
•
# of calls after which trap is sent
after which the trap is set.
boxes.
uses:
to generate a trap when an incoming call is
to generate a trap when a call terminates.
to generate a trap when a call
to generate a trap when a call is
to generate a trap when a
to generate SNMP link up/down
sets the number of calls
Part 2
Setup Mode
box.
SNMP Settings
Generate