6-2. Wiring Examples (for F3SG-SR/PG)
Examples of a motor control system using the F3SG-SR/PG are shown below. This chapter shows examples
equivalent to up to PLe, Category 4 (ISO 13849-1). This does NOT mean that the combination of a system
can always achieve the performance levels and categories under all the similar conditions and situations.
Conformity to the performance levels and categories must be assessed as a whole system. When using
F3SG-SR/PG for performance levels and safety categories, perform the installation, inspection, and
maintenance properly, and be sure to confirm the conformity as a whole system.
6-2-1. Non-Muting System Wiring Examples
6-2-1-1. Auto Reset Mode with Optical Synchronization and EDM Unused
F3SG-SRA
F3SG-SRB
[Wiring Example (F3SG-SR and F3SG-PGA-A/-L)]
F39-JGC-L
[Wiring Example (F3SG-PGA-C)]
F3SG-PGA-A/-L
F3SG-PGA-C
F39-JGC-D
Input/Output Circuit and Applications
Intelligent Tap
Wiring for NPN *1
*7
IN1
IN2
Safety controller
*5 *6
Intelligent Tap
F3SG-JGC-D
Wiring for NPN *1
*7
IN1
IN2
Safety controller
*5 *6
Not needed
24 VDC
24 VDC
Not needed
24 VDC
24 VDC
F3SG-SR/PG
User's Manual
E
383