Omron F3SG-PGA-A User Manual page 275

Safety light curtain f3sg sr series multi-beam safety sensor
Hide thumbs Also See for F3SG-PGA-A:
Table of Contents

Advertisement

 Fixed Blanking Setup Procedure (Setting by Teach-in)
1.
Select a Fixed Blanking zone, and enable the function (No. 1).
2.
Set up the zone.
Select [Teach-in] in [Setting by]. (No. 2)
Selecting [Teach-in] switches the state to the Teach-in mode.
Block the F3SG-SR/PG in the zone that you wish to set up as the Fixed Blanking zone.
Click the [Execute] button in [Confirm zone] to determine the Fixed Blanking zone between the bottom
and top beams blocked. (No.4)
After the zone is determined, restore the [Setting by] to [Manual]. (No. 2)
3.
Select a Fixed Blanking Monitoring function. (No. 5)
4.
Set up the number of allowable beams. (No. 5)
The allowable beams are configurable inside the Fixed Blanking zone. The set allowable beams will be
indicated in the chart as shown below.
In this example, one upper and two lower beams are set as allowable beams.
The table below describes the number of allowable beams configurable for a Fixed Blanking zone.
Number of allowable beams available for fixed blanking beams
Number of fixed blanking beams
1
2
3
4
n
When you wish to set allowable beams outside the blocked zone in Step 2, add a Fixed Blanking zone outside the
zone determined in Step 2 and then set up allowable beams.
5.
Click the [Write configuration] button. On the settings list which will appear, confirm that the changed
settings are correct, and click the [OK] button.
Maximum number of allowable beams
Setting not possible
1
2
3
n-1
Setting with SD Manager 3
F3SG-SR/PG
User's Manual
E
245