If the sensor configuration (model and cascading) in the Intelligent Tap corresponds with that of the
actual one, the Restoration is automatically performed.(1)
If the sensor configurations differ only in the number of beams, you can forcibly perform the Restoration
with the Push Switch.(2)
If the sensor configuration of other than the number of beams is not the same, perform the Backup of
the connected F3SG-SR/PG and then perform the Restoration again.
After the Restoration is performed, verify that the F3SG-SR/PG operates with intended settings before using the F3SG-
SR/PG.
 LED indication during Restoration
Function
Mode
Transitioning modes
Waiting for Push Switch operation
Transferring data
Restoration
Waiting for restart after Restoration
Waiting for restart due to
unenforceable condition
Waiting for restart due to
communication error
Fast blinking
0.25 s
0.5 s
Slow blinking
1.0 s
State
(Yellow)
2.0 s
Setting with Intelligent Tap
Indicator
IN
OUT
(Green/Red)
Illuminated
OFF
IO-Link
ERR
(Green)
(Red)
--
Fast
Slow
blinking
blinking
F3SG-SR/PG