Setting with Intelligent Tap
Follow the flowchart below to perform the Restoration.
For detailed steps, refer to 3-10-3. Applying Setting Saved in Intelligent Tap to Sensor Using Restoration.
Yes
Intelligent Tap OUT indicator
blinks fast
F3SG-SR/PG
164
User's Manual
Restoration
Power OFF
Activate settings by
Yes
DIP Switch on
Intelligent Tap?
No
Set DIP Switch Position 1on
Intelligent Tap at ON (Lock)
and Positions 2 to 8 at OFF
Connect Intelligent Tap to
F3SG-SR/PG
Power ON
Intelligent Tap OUT indicator
blinks
Actual sensor configuration
corresponds with that in
Intelligent Tap?
Only # of beams unmatched,
Yes
No
(1)
Perform Restoration
(copying settings from
Intelligent Tap to F3SG-SR/PG)
Restoration
successful?
Intelligent Tap OUT indicator
blinks fast and ERR indicator
lights up
Turn OFF power and disconnect
Intelligent Tap from F3SG-SR/PG
Set DIP Switch Position 1 on
Intelligent Tap at ON (Lock),
Position 2 at ON (DIP Switch
Enabled) and set Positions 3 to 8
according to your application
All F3SG-SR/PG indicators
other than ABI or TOP/BTM indicator
blink sequentially.
No
No
other configuration
information matched
Yes
Press and hold
Push Switch for
over 1 sec
Yes
(2)
No
Intelligent Tap IN indicator
blinks fast, OUT indicator
blinks fast, and ERR
indicator lights up
End
If the sensor configuration of
other than the number of
beams is not the same,
perform the Backup of the
connected F3SG-SR/PG
and then perform the
Restoration again.