Function
No.
name
7
Dynamic
Select Enable or Disable,
muting
measurement time and the
number of allowable beams for
the Dynamic Muting function.
Set the measurement time by
moving the pointer of the bar.
8
Statistics data
Select Enable or Disable for recording of muting
recording
statistic data.
9
Time
Moves to the setting screen of muting time
information
information.
setting
10
Override
Set Enable or Disable and time
limit for overriding.
Zone setting is possible for desired channel and beam (in 1-beam increments).
The settings after the zone is determined are displayed in the zone information area under the chart.
• For more information on muting, refer to 2-13. Muting.
• For more information on override, refer to 2-14. Override.
For the following functions, the setting parameters are kept individually in each case that the muting function is set
enabled or disabled. After changing the Muting function from Enable to Disable or from Disable to Enable, check the
settings of these functions again.
Affected functions: External Device Monitoring (EDM), Start Interlock, Restart Interlock, Auxiliary Output
For more information on the setting parameters, refer to:
• 2-8. Interlock
• 2-11. External Device Monitoring (EDM)
• 2-12. Auxiliary Output
When changing the settings is complete, confirm the settings and write the configuration to the F3SG-SR/PG.
To enable the written configuration, refer to 4-2-7-3. Writing Configuration into Intelligent Tap.
When connecting the Intelligent Tap to a F3SG-SR/PG and trying to return the F3SG-SR/PG to [Detecting], follow step 4
of 4-1-3-2. Connection Procedure When Using USB Connector to restart the F3SG-SR/PG and Intelligent Tap, or click
the [Monitor]
button.
 Muting Setup Procedure
1.
Enable the Muting function (No. 1).
2.
Select a muting type (No. 2).
3.
Set up a zone (Refer to
4.
As needed, set up the Dynamic Muting function (No. 7).
5.
As needed, set up the Statistics Data Recording function (No. 8).
6.
Set up muting time information (Refer to
7.
As needed, set up the Override function (No. 10).
8.
Click the [Write configuration] button. On the settings list which will appear, confirm that the changed
settings are correct, and click the [OK] button.
Description
Dynamic muting
Measurement
time
Number of
allowable beams
Override
Override input
time limit
Override time limit 600 s
Muting Zone Setup Procedure below.) (Nos. 4, 5, and 6).
Setting of Muting Time Information below.) (No. 9).
Setting with SD Manager 3
Configurable value or numerical
Initial value
range
Disable
Disable/Enable
3 s
1 to 25 s (in 0.1 s increments)
1
0 to 5 beams
(in 1-beam increments)
Enable
Disable/Enable
-
-
Enable
Disable/Enable
1 s
0.1 to 5 s (in 0.1 s increments)
0 to 600 s
(in 1-s increments)/ (Infinite when 0
is set)
E