 Setting with End Cap
Scan code can be set as code A or B by changing the termination cap. The termination cap for
functional setting is attached on the TOP side. To change the scan code, replace the terminal cap
before installing F3SG-SR/PG. Replace the termination cap after turning OFF the power. In the Wired
Synchronization*, selecting a scan code is unnecessary. When using the F3SG-SR in cascade
connection, make sure to attach the End Cap to the secondary sensor farthest from its power supply.
End Cap
* In the Wired Synchronization, F3SG-SR can prevent mutual interference in up to 3 sets.
Loosen the fixing screws (at 2 locations) of the End Cap connected near the "TOP" mark of the F3SG-
SR/PG and remove the End Cap as shown below. Connect the replacing End Cap to the F3SG-SR/PG
and tighten the fixing screws to fix the End Cap. The recommended torque to tighten the Mounting
Screws is 0.35 N·m.
End Cap fixing screw (at 2 locations)
M2.5 screw (Tightening torque: 0.35 N ・ m)
- Do not remove the insulating rubber attached to the End Cap. Failure to do so may cause deterioration of the protective
functions.
- When attaching the End Cap, tightly fasten the screw (M2.5, recommended torque: 0.35 N·m). Failure to do so may
cause the End Cap to come loose, leading to deterioration of the protective functions.
- The insulating rubber attached to connector of the End Cap may come off when removing the End Cap. If the rubber
comes off, place it back to the groove of the connector and insert the connector to the sensor body.
- Change only the End Cap on the emitter/receiver for F3SG-PGA-C.
 Setting with Lamp (optional: F39-SGLPT)
Using the rotary switch of the lamp, you can configure the scan code to either code A or B.
For how to configure, refer to 2-26-1. Functional Description  Scan Code Switching by Lamp on
Optical Synchronization.
Description
Scan Code A (factory
default setting)
Scan Code B
Marking on plastic part
"TOP" mark
System Operation and Functions
Color
Black