Omron F3SG-PGA-A User Manual page 340

Safety light curtain f3sg sr series multi-beam safety sensor
Hide thumbs Also See for F3SG-PGA-A:
Table of Contents

Advertisement

Wiring and Installation
 Side Mounting
Dimension C 4-digit number of the type name (Protective height: )
Dimension D
Dimension P
5-3-4-1. Mounting with Side-Mount Brackets (Intermediate Brackets) (F39-LSGF)
- Use the brackets of specified quantities and locations according to the dimensions. The other brackets than described
above may not meet the specified ratings and performance.
- When you use the sensor in a situation where the sensor is under a load, increase the number of the brackets used.
- Beam alignment cannot be performed with Side-Mount Brackets.
F3SG-SR/PG
310
User's Manual
50
38
Side-Mount
Bracket
(F39-LSGF)
Side-Mount
Bracket
(F39-LSGF)
19.4
C-170
F3SG-4PGA0670-2
F3SG-4PGA0970-3
F3SG-4PGA1070-4
F3SG-4PGA1370-4
32
46.7
Dimension C
0670 to 1370
500
400
* The number of brackets required to mount either one side of the sensor
300
(emitter, receiver, emitter/receiver, or passive mirror)
400
2-M5
or
M6
2-M5
or
M6
<Screw: M5 or M6>
[ Unit : mm ]
Number of Side-
Dimension F
Mount Bracket *
2
1000mm max.

Advertisement

Table of Contents