Omron F3SG-PGA-A User Manual page 44

Safety light curtain f3sg sr series multi-beam safety sensor
Hide thumbs Also See for F3SG-PGA-A:
Table of Contents

Advertisement

Overview and Specifications
Location Indicator
8
-
Top-beam-
9
TOP
state
10
BTM
*1. Refer to 8-1. Troubleshooting for more information on blinking patterns.
*2. Configurable by SD Manager 3.
*3. This is the case for the Standard Muting mode. For other muting modes, refer to 2-13. Muting.
*4. The Area Beam Indicator closer to the "TOP" mark on the F3SG-SR blinks.
*5. The Area Beam Indicator closer to the "BTM" mark on the F3SG-SR blinks.
*6. DIP switches is on the Intelligent Tap.
In the SETTING state to make settings with the SD Manager 3, the TEST, LONG and CODE indicators on the emitter
and the CFG, PNP and CODE indicators on the receiver blink.
(TEST: Yellow, LONG/CODE: Green, CFG/PNP/CODE: Green)
For more information on the statuses of the LED indicators in the SETTING state, refer to
of F3SG-SR/PG with SD Manager 3 Connected.
F3SG-SR/PG
14
User's Manual
Name
Color
Illuminated
The target beams of the
ABI are unblocked and
Green
the safety outputs are
turned ON
Incident light level of the
target beams of the ABI
is 170% (factory default
setting (*2)) or less of
ON-threshold (for 5 to 10
s)
Orange
Area
Beam
Indicator
(ABI)
The target beams of the
ABI are blocked
Red
The target beams of the
ABI are unblocked (The
ABI then will be
OFF
illuminated in green when
the safety outputs are
turned ON.)
The top beam is
Blue
unblocked
Bottom-
The bottom beam is
beam-
Blue
unblocked
state
Blinking
MUTING or OVERRIDE state. In the
MUTING state, only the ABI
indicators in the muting zone are
blinking. Or the target beams of the
ABI are blocked instantaneously
Incident light level of the target beams
of the ABI is 170% (factory default
setting (*2)) or less of ON threshold 5
to 10 s after illuminated when incident
light level of the target beams of the
ABI is 170% (factory default setting
(*2)) or less of ON threshold. Or one
muting input becomes the ON state
and the MUTING state has not been
started yet, or one muting input
becomes the OFF state and the other
is not in the OFF state yet. (*3)
LOCKOUT state due to Cap error or
Other sensor error (*4), or LOCKOUT
state due to DIP Switch setting error
(*5 *6)
-
MUTING/OVERRIDE state, or
LOCKOUT state due to Cap error or
Other sensor error
MUTING/OVERRIDE state, or
LOCKOUT state due to DIP Switch
setting error (*6)
F3SG-
F3SG-
F3SG-
SRA
SRB
PG
X
-
-
X
-
X
4-1-4. SETTING State

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sg pg seriesF3sg-pga-lF3sg-pga-c