Overview and Specifications
- Optical synchronization
Maximum cable extension (Load condition: Safety outputs 1 and 2: 60 mA, Auxiliary output : 60 mA)
Sensor
Cascading
(1),(2),(3),(4)
(5)
(6)
(6)+(7)
*1. (8) must be 20 m max.
*2. Under the maximum load conditions (safety outputs 1 and 2 of 300 mA per channel and auxiliary output of 100 mA), the cable
extension must be 50% max. of the length listed in the table.
*3. Conditions exist for the use of the F3SG-4SRA in 2-segment or 3-segment cascade. Refer to 1-5-1. F3SG-SR Series –
Electrical – Safety outputs (OSSD).
*4. Not including the Cascading Cable for Extended (F39-JGR3W) and the Root-Plug Cable for Extended (F39-JGR3K).
<Using Y-Joint Plug/Socket Connector (F39-GCNY2)>
Maximum cable extension (Load condition: Safety outputs 1 and 2: 60 mA, Auxiliary output : 60 mA)
Sensor
Cascading
(1),(2),(3),(4)
L: (5)+(7)
(6)+(7)
*1. Under the maximum load conditions (safety outputs 1 and 2 of 300 mA per channel and auxiliary output of 100 mA), the cable
extension must be 50% max. of the length listed in the table.
*2. Conditions exist for the use of the F3SG-4SRA in 2-segment or 3-segment cascade. Refer to 1-5-1. F3SG-SR Series –
Electrical – Safety outputs (OSSD).
*3. Not including the Cascading Cable for Extended (F39-JGR3W) and the Root-Plug Cable for Extended (F39-JGR3K).
F3SG-SR/PG
28
User's Manual
(1)
(3)
Emitter
Receiver,
(2)
(4)
Emitter/Receiver
F3SG-SR *2
Single
2-segment *3
10 m each *4
100 m
50 m
100 m
100 m
(1)
(3)
Emitter
Receiver,
(2)
(4)
Emitter/Receiver
F3SG-SR *1
Single
2-segment *2
10 m each *3
100 m
70 m
(5)
(8)*1
Power
IO-Link
supply
master
Power
supply
(6)
(7)
F3SG-PG *2
3-segment *3
Single
None
100 m
50 m
80 m
100 m
(5)
Power
supply
(6)
(7)
Y-Joint Plug/
Socket Connector
(F39-GCNY2)
L = 100 to 60 m
F3SG-PG *1
3-segment *2
Single
None
60 m
100 m
F3SG-SR-K *2
Single
None
100 m
50 m
100m
F3SG-SR-K *1
Single
None
100 m