Omron F3SG-PGA-A User Manual page 220

Safety light curtain f3sg sr series multi-beam safety sensor
Hide thumbs Also See for F3SG-PGA-A:
Table of Contents

Advertisement

Setting with Intelligent Tap
 If intelligent tap's ERR indicator is red ON
The sensor model and/or configuration settings stored in the intelligent tap differ from those that are
actually connected. Use SD Manager 3 to modify the settings stored in the intelligent tap so that they
should correspond with the actual sensor configuration, and go back to step 3. to perform the steps
again.
 If the OUT indicator of the intelligent tap flashes green in 2.0 second cycle
The restoration is not performed.
The number of beams of the sensor stored in the intelligent tap differs from that of the sensor actually
connected.
If a function related to the number beams is used, such as blanking, use SD Manager 3 to modify the
settings stored in the intelligent tap so that they should correspond with the actual sensor
configuration, and go back to step 3. to perform the steps again.
If no function is used that is related to the number of beams, press and hold the Push switch of the
intelligent tap for 1 second or longer. Restoration starts.
8.
Turn off power of the intelligent tap and F3SG-SR/PG, then turn on power of them.
The settings are not enabled unless the intelligent tap and F3SG-SR/PG are restarted.
9.
Check that F3SG-SR/PG runs as intended.
If it does not, use SD Manager 3 to check the settings, and go back to step 3. to perform the steps
again.
10.
Turn off power of the intelligent tap and F3SG-SR/PG.
F3SG-SR/PG
190
User's Manual
®
Bluetooth
Push-SW
Communication Unit
Connector
USB Type-C
DIP-SW
Connector
<Status of indicators at abnormal number of
beams/configuration error>
IN
:Flashing yellow at 0.5 second cycle
(quick flashing)
OUT :Flashing green at 0.5 second cycle
(quick flashing)
ERR :Red ON
<Status of indicators at abnormal number of
beams>
OUT :Flashing green at 2.0 second cycle
(slow flashing)
ERR :Not lit
TM

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sg pg seriesF3sg-pga-lF3sg-pga-c

Table of Contents