Wiring Examples; Edm Disabled, Manual Reset Mode, External Test In 24 V Active(Used), Muting Disabled And Pnp Outputs - Omron F3SG-*RR Series Quick Installation Manual

Safety light curtain
Hide thumbs Also See for F3SG-*RR Series:
Table of Contents

Advertisement

Setting

5.Wiring Examples

For input/output circuit and other examples than below, refer to Safety Light Curtain F3SG-RR Series User's Manual.
5-1. EDM enabled, Auto Reset Mode, External Test in 24 V Active (not
used), Muting disabled and PNP Outputs
□□
F39-JD
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
M: 3-phase motor
*1. The functions are configurable with Configuration Tool. Refer to Safety Light Curtain Configuration Tool for Model F3SG (SD
Manager 2) User's Manual for more information on setting the functions by the Configuration Tool.
*2. Connect the line to 24 V via a test switch (N.O. contact) if External Test is used.
*3. Connect a lockout reset switch (N.C. contact) to this line in series with the KM1 and KM2 if Lockout Reset is used.
*4. Used as MUTE A and B lines when Muting is used.
*5. The F39-JD
RA-L Single-Ended Cable for Emitter (Oil-Resistant Extension Cable) does not have the red, white and yellow wires.
*6. For the F39-JD
A-
Single-Ended Cable, connect the shield line to 0 V.
5-2. EDM disabled, Manual Reset Mode, External Test in 24 V Active(used),
Muting disabled and PNP Outputs
□□
F39-JD
S1
S1: Test Switch (Connect the line to 0 V if this switch is not required)
S2: Lockout/Interlock Reset Switch
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
M: 3-phase motor
*1. Also used as EDM line.
*2. The functions are configurable with Configuration Tool. Refer to Safety Light Curtain Configuration Tool for Model F3SG (SD
Manager 2) User's Manual for more information on setting the functions by the Configuration Tool.
*3. Used as MUTE A and B lines when Muting is used.
*4. The F39-JD
RA-L Single-Ended Cable for Emitter (Oil-Resistant Extension Cable) does not have the red, white and yellow wires.
*5. For the F39-JD
A-
Single-Ended Cable, connect the shield line to 0 V.
F3SG-RR
Quick Installation Manual
Wiring
□□
A-L *6
F39-JD
A-D *6
KM1 KM2
KM1
KM2
□□
A-L *5
F39-JD
A-D *5
S2
KM1 KM2
Mounting/Beam Alignment
[Settings]
EDM Enabled (factory default setting) *1
Receiver
Auto Reset (factory default setting) *1
PNP (factory default setting) *1
External Test: 24 V Active (End Cap:
Emitter
Black) (factory default setting)
+24 VDC
Power Supply
0 VDC
[Settings]
EDM Disabled *2
Receiver
Manual Reset *2
PNP (factory default setting) *2
External Test: 24 V Active (End Cap:
Emitter
Black) (factory default setting)
+24 VDC
Power Supply
0 VDC
Operation check
Function
KM1
KM2
M
Function
KM1
KM2
M
4

Advertisement

Table of Contents
loading

Table of Contents