Omron F3SG-PGA-A User Manual page 55

Safety light curtain f3sg sr series multi-beam safety sensor
Hide thumbs Also See for F3SG-PGA-A:
Table of Contents

Advertisement

Model
Electrical
Input voltage
TEST
OPERATING
RANGE
SELECT
INPUT
RESET/EDM
MUTE A/B ,
PRE-RESET
*The Vs indicates a supply voltage value in your environment.
Overvoltage category
(IEC 60664-1)
Indicators
Protective circuit
Insulation resistance
Dielectric strength
Functional
Mutual interference prevention
Test function
Safety-related functions
F3SG-4SRB-14-K
Light emission stops when connected to 24 VDC
ON voltage: Vs-3 V to Vs (short circuit current: approx. 5.0 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 6.0 mA) *
Light emission stops when connected to 0 V
ON voltage: 0 to 3 V (short circuit current: approx. 6.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 5.0 mA) *
Long: 12 V to Vs (short circuit current: approx. 4.2 mA) * or open
Short: 0 to 3 V (short circuit current: approx. 4.2 mA)
PNP
ON voltage: Vs-3 V to Vs (short circuit current: approx. 9.5 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 13.0 mA) *
NPN
ON voltage: 0 to 3 V (short circuit current: approx. 13.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 9.5 mA) *
PNP
ON voltage: Vs-3 V to Vs (short circuit current: approx. 4.5 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 7.0 mA) *
NPN
ON voltage: 0 to 3 V (short circuit current: approx. 7.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 4.5 mA) *
II
See 1-4. LED Indicators on F3SG-SR/PG for more information.
Output short-circuit protection
20 M or higher (500 VDC megger)
1,000 VAC, 50/60 Hz (1 min)
Optical synchronization: fixed to Scan Code A
Wired synchronization: in up to 3 sets
See 5-1-4. Mutual Interference Prevention for more information.
Self-test (at power-on, and during operation)
External test (light emission stop function by test input)
Interlock
External Device Monitoring (EDM)
Pre-Reset
PSDI
Fixed Blanking/Floating Blanking
Reduced Resolution
Muting/Override
Mutual Interference Prevention
PNP/NPN Selection
Response Time Adjustment
See Chapter 2 System Operation and Functions and Chapter 3 Setting with
Intelligent Tap for more information.
Overview and Specifications
F3SG-4SRB-25-K
F3SG-SR/PG
User's Manual
E
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sg pg seriesF3sg-pga-lF3sg-pga-c

Table of Contents