4.
If the intelligent tap is not connected yet, connect it to F3SG-SR/PG. Refer to the chart in 3-10-1.
Setting F3SG-SR/PG with DIP Switch, Step 5. to make sure that the system has the configuration
with intelligent tap.
5.
Turn on power of the intelligent tap and F3SG-SR/PG.
6.
Press and hold the Push-SW of the intelligent tap for 1 second or longer.
The setting of F3SG-SR/PG are backed up in the intelligent tap.
7.
Check the indicators if backup is complete.
If the indicators are different from the above, turn off power of the intelligent tap and F3SG-SR/PG,
make sure that the wiring is proper, and go back to step 2. to perform the steps again.
8.
Turn off power of F3SG-SR/PG.
9.
Set the DIP-SW channel 1 ON.
10.
Turn on power of the intelligent tap and F3SG-SR/PG.
11.
Check that F3SG-SR/PG runs as intended.
If it does not, turn off power of the intelligent tap and F3SG-SR/PG, make sure that the wiring is proper,
and go back to step 2. to perform the steps again.
12.
Turn off power of the intelligent tap and F3SG-SR/PG.
®
Bluetooth
Communication Unit
Connector
DIP-SW
®
Bluetooth
Push-SW
Communication Unit
Connector
USB Type-C
DIP-SW
Connector
Setting with Intelligent Tap
Push-SW
USB Type-C
TM
Connector
<Status of indicators at normal end>
OUT :Flashing yellow at 0.5 second cycle
(quick flashing)
ERR :Not lit
DIP-SW
TM
E
F3SG-SR/PG
187
User's Manual