Omron F3SG-PGA-A User Manual page 280

Safety light curtain f3sg sr series multi-beam safety sensor
Hide thumbs Also See for F3SG-PGA-A:
Table of Contents

Advertisement

Setting with SD Manager 3
 Muting Zone Setup Procedure
Select a setup method (No. 4)
[Setting by Manual] (No. 5)
Select a zone No., and set up the bottom and top beam numbers.
Click the [Execute] button in [Confirm zone] to determine the muting zone between the bottom and
top beams configured above. (No. 6)
[Setting by Teach-in]
Selecting [Teach-in] switches the state to the Teach-in mode.
Block the F3SG-SR/PG in the zone that you wish to set up as the muting zone.
Click the [Execute] button in [Confirm zone] to determine the muting zone between the bottom and
top beams blocked. (No. 6)
Select [Manual] in [Setting by] after the zone is determined (No. 4).
 Setting of Muting Time Information
F3SG-SR/PG
250
User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sg pg seriesF3sg-pga-lF3sg-pga-c

Table of Contents