Omron F3SG-PGA-A User Manual page 306

Safety light curtain f3sg sr series multi-beam safety sensor
Hide thumbs Also See for F3SG-PGA-A:
Table of Contents

Advertisement

Setting with SD Manager 3
• Refer to 2-27-4. Power-ON Time for more information on the accumulated power-on time.
• Refer to 2-27-5. Load Switching Frequency for more information on the load switching frequency.
• Writing the configurations of power-on time threshold and load switching frequency threshold to the F3SG-SR/PG is
also possible with the operator level.
• The power-on time information is recorded in the F3SG-SR/PG main unit every 15 minutes.
• When configuring F3SG-SR in a cascade connection, select a desired sensor segment from the [Target sensor] button
• When changing the settings is complete, confirm the settings and write the configuration to the F3SG-SR/PG.
To enable the written configuration, refer to 4-2-7-3. Writing Configuration into Intelligent Tap.
F3SG-SR/PG
276
User's Manual
in the top right corner of the screen.