4-3-4. Safety Function Setting
4-3-4-1. Fixed Blanking
F3SG-SRA
F3SG-SRB
First, carry out 4-3-1. Preparing to Change Settings.
Next, click the icon below on the Top page.
The setting screen below is displayed.
Function
No.
name
1
Blanking zone
This is the number for a target zone of the Fixed
No.
Blanking. Up to three fixed blanking zone can be
configured for each channel.
Fixed
Select Enable or Disable for the Fixed Blanking function
Blanking
for each fixed blanking zone.
When you want to restore the readout settings received
from the F3SG-SR/PG, click [Recover status at readout].
2
Setting by
Select manual setting using SD Manager 3 or setting by
teach-in.
3
Zone setting
To configure zone settings, specify desired bottom and top
beam numbers from the drop-down list, or directly on the
chart. When you check the [Designate from chart] box, you
can specify a zone range by dragging red lines shown on
the chart.
4
Confirm zone
To confirm the setting of the specified zone, execute
[Confirm Zone].
5
Fixed
Select a desired monitoring
blanking
method and number of allowable
monitoring
beams.
F3SG-PGA-A
F3SG-PGA-L
Description
Fixed blanking
monitoring
Number of allowable
upper/lower beams
Setting with SD Manager 3
F3SG-PGA-C
Configurable value or
Initial value
1
1 to 3
Disable
Disable/Enable
Manual/
Manual/Teach-in
• Bottom beam:
Desired beam
Not specified
(in 1-beam increments)
• Top beam: Not
specified
-
Lockout
Disable monitoring/
Lockout/Cancel blanking
zone/Quick blanking
0
0 to 5 beams
(in 1-beam increments)
numerical range
-
E
F3SG-SR/PG
243
User's Manual