 Restrictions on cable extension
The cable extension must satisfy all the following conditions.
<Intelligent Tap not used>
- Wired synchronization
(1)
(2)
- Optical synchronization
(1)
(2)
* Not including Cascading Cable for Extended (F39-JGR3W) and Root Cable (F39-JGR3K).
In addition, cascade connection function is not supported by F3SG-PG and F3SG-SR-K series.
<Intelligent Tap used>
- Wired synchronization
(1)
(2)
Maximum cable extension (Load condition: Safety outputs 1 and 2: 60 mA, Auxiliary output: 60 mA)
Sensor
Cascading
Single
(1),(2),(3),(4)
(5),(6)
(5)+(7)
100 m
(6)+(7)
*1. (8) must be 20 m max.
*2. Under the maximum load conditions (safety outputs 1 and 2 of 300 mA per channel and auxiliary output of 100 mA), the cable
extension must be 50% max. of the length listed in the table.
*3. Conditions exist for the use of the F3SG-4SRA in 2-segment or 3-segment cascade. Refer to 1-5-1. F3SG-SR Series –
Electrical – Safety outputs (OSSD).
*4. Not including the Cascading Cable for Extended (F39-JGR3W) and the Root-Plug Cable for Extended (F39-JGR3K).
(3)
(5)
Emitter
Power
supply
Receiver,
(4)
(6)
Emitter/Receiver
(3)
(5)
Power
Emitter
supply
Power
Receiver,
supply
(4)
(6)
Emitter/Receiver
(3)
(5)
Emitter
Receiver,
(4)
(6)
Emitter/Receiver
F3SG-SR *2
2-segment *3
3-segment *3
10 m each *4
50 m each
70 m
60 m
Overview and Specifications
Maximum extionsion length
(1) to (4): 10 m each *
(5) to (6): 100 m each
Maximum extionsion length
(1) to (4): 10 m each *
(5) to (6): 100 m each
(8)*1
IO-Link
master
Power
supply
(7)
F3SG-PG *2
F3SG-SR-K *2
Single
Single
None
None
50 m each
50 m each
100 m
100 m
F3SG-SR/PG
E
27
User's Manual