MX480 Universal Routing Platform Hardware Guide
Action
296
On a regular basis:
Check the LEDs on the craft interface directly above each MPC slot. The green LED
labeled
lights steadily when an MPC is functioning normally.
OK
Check the
OK/FAIL
LED on the MPC. If the MPC detects a failure, the MPC sends an
alarm message to the Routing Engine.
Issue the CLI
show chassis fpc
shown in the sample output, the value
that the MPC is functioning normally:
user@host> show chassis fpc
Temp
Slot State
(C)
0
Online
36
1
Online
40
2
Online
41
3
Online
43
4
Online
24
5
Empty
For more detailed output, add the
a slot number, which is optional:
user@host> show chassis fpc detail
Slot 0 information:
State
Temperature
Total CPU DRAM
Total RLDRAM
Total DDR DRAM
Start time:
Uptime:
Max Power Consumption
Slot 1 information:
State
Temperature
Total CPU DRAM
Total RLDRAM
Total DDR DRAM
Start time:
Uptime:
Max Power Consumption
Slot 2 information:
State
Temperature
Total CPU DRAM
Total RLDRAM
Total DDR DRAM
Start time:
Uptime:
Max Power Consumption
Slot 3 information:
command to check the status of installed MPCs. As
Online
in the column labeled
CPU Utilization (%)
Memory
Total
Interrupt
DRAM (MB) Heap
3
0
2048
5
0
2048
6
0
1024
5
0
1024
3
0
1024
option. The following example does not specify
detail
Online
33 degrees C / 91 degrees F
1024 MB
256 MB
4096 MB
2009-12-22 12:26:54 PST
6 days, 3 hours, 8 minutes, 51 seconds
330 Watts
Online
32 degrees C / 89 degrees F
1024 MB
256 MB
4096 MB
2009-12-22 12:26:54 PST
6 days, 3 hours, 8 minutes, 51 seconds
365 Watts
Online
41 degrees C / 105 degrees F
1024 MB
128 MB
2048 MB
2009-12-22 12:26:46 PST
6 days, 3 hours, 8 minutes, 59 seconds
265 Watts
State
indicates
Utilization (%)
Buffer
14
13
26
13
7
43
16
57
13
21