MX480 Universal Routing Platform Hardware Guide
198
Reinstalling the Power Supplies After Installing the MX480 Router Without a Lift
Reinstall the rightmost power supply first, and then work your way to the left. To reinstall
the AC or DC power supplies, follow this procedure for each power supply (see
Figure 65 on page
198, which shows the installation of the DC power supplies):
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
1.
ESD points on the chassis.
On an AC-powered router, switch the AC input switch on each power supply to the
2.
off (
) position. On a DC-powered router, Move the DC circuit breaker on each DC
O
power supply to the off (
We recommend this even though the power supplies are not connected to power
sources.
Using both hands, slide the power supply straight into the chassis until the power
3.
supply is fully seated in the chassis slot. The power supply faceplate should be flush
with any adjacent power supply faceplate or blank installed in the power supply slot.
Tighten the captive screws.
4.
Figure 65: Reinstalling a Power Supply
Reinstalling the Fan Tray After Installing the MX480 Router Without a Lift
To reinstall the fan tray (see
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
1.
ESD points on the chassis.
O
) position.
Figure 66 on page
199):
Copyright © 2019, Juniper Networks, Inc.