When M3 is ON (at this time, the value in D206 is ignored), VFD decelerates to stop after receiving the stop command.
4.
When M4 is ON, the instruction reads the values of H2100–H2104 of VFD and stores them in D220–224.
Device
Content
Error code
The state of the VFD:
Bit2=1 causes the VFD to execute the Jog command. Bit4–3=11B causes the VFD to run counterclockwise. The
frequency command is 18000, and causes the VFD to run at 180Hz. For the definitions of the parameter addresses
in the communication protocol, refer to the Delta AC Motor Drive user manual.
5.
The reception completion flag SM100 is ON, and the values of M1–M5 are cleared to avoid interfering with the next
communication command.
After receiving the data that the VFD sends back, the instruction checks the format of the data sent back from VFD.
If the data format is correct, SM100 is ON; otherwise, SM102 is ON.
D220
D221
VFD state
Cha p ter 6 App l ied Ins truc tio ns
D222
D223
Frequency
Output frequency
command
D224
Output current
6_
6 - 6 7 9