AS Ser ies Pro gra mm in g M anu al
API
Instruction
2818
D
Device
X
Node
TarSpd
LimitTQ
CurTQ
Reach
Err
Data type
Node
TarSpd
LimitTQ
CurTQ
Reach
Err
Symbol:
_6
Explanation
1.
Make sure that all Delta drives have been initialized before executing this instruction.
2.
For execution of this instruction, you need to use PLC FW V1.06.20 or later and ISPSoft V3.07 or later.
3.
For Delta Servo Drives: set the parameter P1-01 to 3 (T: Torque Control mode) and turn the power off and on
again for the setting to be effective.
For Delta Vector Control Drives: use ASDON instruction to set Torque Control mode and set the parameter P00-20
(source of master frequency command (AUTO)) to 6 (CANopen communication card) on Delta AC Motor Drives
that supports torque control mode.
4.
Node: the Node ID of Delta Servo Drives and Delta AC Motor Drives, ranging from 1 to 8 (Delta Servo Drives) and
21 to 28 (Delta AC Motor Drives). If the setting is out of the range, Err flag will be ON.
6 - 1 0 5 8
TQLC
Node、TarSpd、...、Err
Y
M
S
T
C
Operand
HC
D
FR
SM
Pulse Instruction
16-bit instruction
: Node ID of Delta drives
Node
TarSpd : Specified target speed
LimitTQ : Maximum torque
CurTQ : Target torque is reached
Reach : Communication error flag
: Target torque is reached
Err
Description
Speed of torque control
SR
E
K
16#
32-bit instruction
"$"
F
AS